SB 326 INSPECTIONS FOR VACAVILLE HOAs
SB 326 Inspection
in Vacaville, CA
North American Construction Services inspects exterior elevated elements for Vacaville HOAs and property managers, a short drive up I-80 from our North Highlands office. A licensed engineer on our staff signs every SB 326 report.
What SB 326 Requires of
Vacaville Condo Associations
Vacaville's condominium and townhome communities sit in one of the hottest parts of the Bay Area–Sacramento corridor. That heat is hard on balconies. If your association maintains wood-supported balconies, decks, stairways or walkways more than six feet above the ground, SB 326 (Civil Code §5551) requires a licensed engineer or architect to inspect them.
SB 326 (Civil Code §5551) applies to condominium associations with buildings of three or more units. A licensed structural engineer, civil engineer or architect must inspect a random, statistically significant sample of the wood-supported balconies, decks, stairways and walkways more than six feet above the ground, along with their waterproofing, at least every nine years. The findings go to the board and into the reserve study.
For the full requirements, see our SB 326 inspection overview.
Need Repairs After Inspection?
We’ve Got You Covered.
If your SB 326 inspection reveals issues, we’ll refer you to our trusted sister company, Good Life Construction, experts in HOA compliance repairs. Fast, professional work — no stress.
How Vacaville's Heat Leads to Hidden Rot
Summer days well over 90 degrees, strong sun and cool nights make walking-surface coatings, sealants and stucco expand and contract over and over. Over time they crack. Nothing seems wrong during the dry season, but the first winter storms push water through those cracks into the plywood and joists, where it can stay for months.
That is why balconies that look fine on top can still have decay underneath. We look at the walking surface, the soffit below and the connection to the wall, and the inspector decides where a closer look is needed.
What We Check in Vacaville
- Cracked coatings and sealants on walking surfaces
- Stucco cracks along balcony and stair connections
- Staining or soft wood at soffits
- Stair stringers and posts near irrigated landscaping
After the Inspection in Vacaville
The board receives the report, and its findings go into the reserve study. If the inspection finds an immediate threat to safety, a copy must go to the City of Vacaville within 15 days, and the association must restrict access to that element right away.
Structural repairs usually need a building permit from the City of Vacaville. Our report sorts findings by urgency so the board can plan repairs in a sensible order.
How We Inspect Vacaville Properties
- Scope and free quote, including the sample size.
- Site visit in Vacaville, with moisture meters, infrared imaging and borescope cameras for framing that is hard to see.
- Report signed by our licensed engineer, usually within 1–3 business days of the visit.
- A walkthrough of the findings with your board or manager, and a plan for anything urgent.
SB 326 Inspection Cost in Vacaville
Most small and mid-size Northern California associations pay roughly $1,500 to $5,000 per building; large communities are priced by the number of elements in the sample. Every Vacaville quote is free and in writing.
Why Vacaville HOAs Choose Us
- Licensed engineer on staff signs every SB 326 report
- Friendly, HOA-focused communication
- Knowledge of city-specific reporting standards
- Reports designed for easy board review
- 500+ inspections completed across California
Our Balcony
Inspectors
Vacaville SB 326 Inspection FAQ
Schedule Your Vacaville
SB 326 Inspection
Call (916) 550-3055 (Monday–Friday, 8:00 AM–5:00 PM) or request an inspection online. Tell us the number of buildings and elevated elements, and we will reply with a written quote.