SB 326 INSPECTIONS FOR CONCORD HOAs

SB 326 Inspection
in Concord, CA

North American Construction Services inspects exterior elevated elements for Concord HOAs and property managers. Our reports are signed by a licensed engineer on our staff and organized so the board can see what is urgent, what can be planned and what is fine.

Trusted by 500+ Property Owners
NADB Reviews 5/5 Rating

The first SB 326 deadline was January 1, 2025. If your Concord association has not been inspected yet, schedule now.
✕

What SB 326 Requires of
Concord Condo Associations

Concord is home to many condominium and townhome communities built decades ago, long before today's balcony waterproofing details became standard. For associations with wood-supported balconies, decks, stairs or walkways more than six feet above the ground, SB 326 (Civil Code §5551) requires a licensed engineer or architect to inspect those elements at least every nine years.

SB 326 (Civil Code §5551) applies to condominium associations with buildings of three or more units. A licensed structural engineer, civil engineer or architect must inspect a random, statistically significant sample of the wood-supported balconies, decks, stairways and walkways more than six feet above the ground, along with their waterproofing, at least every nine years. The findings go to the board and into the reserve study.

For the full requirements, see our SB 326 inspection overview.

*Apartment buildings that are not part of a condo association or HOA need an SB 721 inspection instead.
✕

Why Connections Matter on Concord Buildings

The Concord Fault runs beneath the city and creeps slowly, a few millimeters a year, without waiting for an earthquake. The U.S. Geological Survey has tracked that creep on the northern part of the fault since 1979, and in 2025 it reported a newly identified creeping strand running south of downtown toward Lime Ridge.

Slow movement puts steady stress on rigid connections. On older condo buildings we pay close attention to the ledger line where a balcony meets the wall, the joints between elevated walkways and the building, and stair landings, because cracks there are often how water gets into the framing. Hot, dry summers that crack coatings make the problem worse once winter rain arrives.

What We Check in Concord

  • Separations and cracked stucco at balcony and walkway connections
  • Flashing at the deck-to-wall joint and at door thresholds
  • Stair stringers and landings, especially where sprinklers wet the lower framing
  • Corroded or missing connectors at joist hangers and posts

Reports, City Notices and Repairs in Concord

Under SB 326, the finished report goes to your board, and its findings belong in the association's reserve study. If the inspector finds a condition that is an immediate threat to safety, a copy must go to the City of Concord within 15 days, and the association must keep people off the affected element until repairs are approved.

Apartment buildings work differently here. Concord's Multi-Family Inspection Program asks SB 721 inspectors to send their reports to the city as well as the owner, so if your company also manages rentals in Concord, plan for that extra step on those buildings. Repairs to load-bearing framing typically need a building permit from the City of Concord, and our sister company, Good Life Construction, handles SB 326 repairs if you need a contractor.

How We Inspect Concord Properties

  1. Scope and free quote, including the sample size.
  2. Site visit in Concord, with moisture meters, infrared imaging and borescope cameras for framing that is hard to see.
  3. Report signed by our licensed engineer, usually within 1–3 business days of the visit.
  4. A walkthrough of the findings with your board or manager, and a plan for anything urgent.

SB 326 Inspection Cost in Concord

Most small and mid-size Northern California associations pay roughly $1,500 to $5,000 per building; large communities are priced by the number of elements in the sample. Every Concord quote is free and in writing.

Serving Concord and Nearby Cities

Service Area

SB 326 inspections near Concord:
Walnut Creek · Martinez · Antioch

CALL AN EXPERT

Why Concord HOAs Choose Us

  • Licensed engineer on staff signs every SB 326 report
  • Friendly, HOA-focused communication
  • Knowledge of city-specific reporting standards
  • Reports designed for easy board review
  • 500+ inspections completed across California

Our Balcony
Inspectors

Dmitriy Tupikov

OWNER/INSPECTOR

Alex Tupikov

OWNER/INSPECTOR

Andrey Tupikov

OWNER/INSPECTOR

Steffen Gilbert

VICE PRESIDENT

DECKS AND BALCONIES
SERVICED

4000+

YEARS
OF EXPERIENCE

36

TRUSTED BY
CUSTOMERS

500+

ASSETS
PROTECTED

$5M+

Concord SB 326 Inspection FAQ

Our Concord buildings sit near the Concord Fault. Does SB 326 require a seismic evaluation?

How many balconies will you actually inspect at our complex?

What happens if the inspection finds problems?

Can the SB 326 inspection be timed with our reserve study?

Schedule Your Concord
SB 326 Inspection

Call (916) 550-3055 (Monday–Friday, 8:00 AM–5:00 PM) or request an inspection online. Tell us the number of buildings and elevated elements, and we will reply with a written quote.